Address
304 North Cardinal
St. Dorchester Center, MA 02124

Work Hours
Monday to Friday: 7AM - 7PM
Weekend: 10AM - 5PM

MIN Inverter/3600/4200/4600/5000/6000TL-X

  1. Secondary lightning protection at DC side
  2. Optional AFCI
  3. Maximum conversion efficiency 98.4%
  4. Dual MPPT
  5. Wide MPPT voltage range
  6. Lightweight and beautiful, compact structure design, can be installed by one person
  7. Touch key, OLED display
Category: Tag:

Description

MIN 3000TL-X  Inverter MIN 3600TL-X Inverter MIN 4200TL-X Inverter MIN 4600TL-X Inverter MIN 5000TL-X Inverter MIN 6000TL-X Inverter
Input data (DC)
Maximum DC input power 4200W 5040w 588Ow 6440W 7000W 8100W
Maximum DC input voltage 100V 550V 550V 550V 550V 550V
Starting voltage 100V 100V 10OV 10OV 100V 100V
MPPT working voltage range/rated input voltage 80V-550V /360V 80V-550V /360V 80V-550V /360V 80V-550V /360V 80V-550V /360v 80V-550V /360v
Maximum input current of each MPPT 13.5A 13.5A 13.5A 13.5A 13.5A 13.5A
MPPT quantity/MPPT of each circuit 2/1+1 2/1+1 2/1+1 2/1+1 2/1 +1 2/1+1
Number of output data (AC) strings
Rated AC output power 3000w 3600w 420Ow 4600W 500Ow 6000w
Maximum AC output power 3300VA 3960VA 4620VA 5060VA 5500VA 660OVA
Maximum AC transmission current 14.4A 17.2A 20A 22A 23.9A 28.7A
Rated output voltage/range 220V/160-300v 220V/160-300v 220V/160-300V 220V/160-300V 220V/160-300v 220V/160-300V
Rated grid frequency/range 50Hz60Hz/±5Hz 50Hz60Hz/±5Hz 50Hz60Hz/±5Hz 50Hz,60Hz/±5Hz 50Hz60Hz/±5Hz 50Hz60Hz/±5Hz
power factor 1 1 1 1 1 1
Power factor adjustment range 0.8 lead – 0.8 lag 0.8 lead – 0.8 lag 0.8 lead – 0.8 lag 0.8 lead – 0.8 lag 0.8 lead – 0.8 lag 0.8 lead – 0.8 lag
AC connection type L+N+PE L+N+PE L+N+PE L+N+PE L+N+PE L+N+PE
efficiency
Maximum efficiency 0.982 98.2% 0.984 0.984 98.4% 98.4%
European weighted efficiency 97% 0.97 97.1% 97.1% 0.972 0.972
MPPT efficiency 0.999 99.9% 99,9% 99.9% 99.9% 99.9%
Equipment protection
DC polarity reverse connection protection YES YES YES YES YES YES
DC input switch YES YES YES YES YES YES
AC output overcurrent protection YES YES YES YES YES YES
AC output overvoltage protection YES YES YES YES YES YES
“Earth fault monitoring YES YES YES YES YES YES
Power grid monitoring“ YES YES YES YES YES YES
Residual current detection module YES YES YES YES YES YES
General data
“Size (width/height/thickness) mm 375/350/158 375/350/158 375/350/158 375/350/158 375/350/158 375/350/158
Weigh 10.8kg 10.8kg 10.8kg 10.8kg 10.8kg 10.8kg
Operating temperature range -35℃…+60C -35℃…+60C -35℃… +60C -35℃..+60C -35℃…+60C -35℃…+60C
Altitude No derating below 3000m No derating below 3001m No derating below 3002m No derating below 3003m No derating below 3004m No derating below 3005m
Self-consumption at night <0.5 W <0.5 W <0.5 W <0.5 W <0.5 W <0.5 W
topological structure No transformer No transformer No transformer No transformer No transformer No transformer cooling cooling cooling cooling cooling cooling cooling cooling cooling
Cooling mode Natural cooling Natural cooling Natural cooling Natural cooling Natural cooling Natural cooling protection protection protection protection protection protection
Protection grade IP65 IP65 IP65 IP65 IP65 IP65
relative humidity 0~100%, non-condensing 0~101%, non-condensing 0~102%, non-condensing 0~103%, non-condensing 0~104%, non-condensing 0~105%, non-condensing features features features features
features
DC input connector H4/MC4 (optional) H4/MC5 (optional) H4/MC6 (optional) H4/MC7 (optional) H4/MC8 (optional) H4/MC9 (optional)
AC output connector Connector Connector Connector Connector Connector Connector
display OLED+LED/WlFI+APP OLED+LED/WlFI+APP OLED+LED/WlFI+APP OLED+LED/WlFI+APP OLED+LED/WlFI+APP OLED+LED/WlFI+APP
Communication interface: RS485/USB/RF/Wi-Fi/GPRS/4G Yes/Yes/Optional/Yes/Yes/Optional Yes/Yes/Optional/Yes/Yes/Optional Yes/Yes/Optional/Yes/Yes/Optional Yes/Yes/Optional/Yes/Yes/Optional Yes/Yes/Optional/Yes/Yes/Optional Yes/Yes/Optional/Yes/Yes/Optional

Reviews

There are no reviews yet.

Be the first to review “MIN Inverter/3600/4200/4600/5000/6000TL-X”